VARIATION IN THE SIZE OF ABDOMINAL AORTA MEASURED ON COMPUTED TOMOGRAPHY

Authors

  • Dolly Sharma Department of Medical Imaging Technology, Charotar Institute of Paramedical Sciences, Charusat University, Changa, Gujarat, India.
  • Visakh T Department of Medical Imaging Technology, SOAHS, Manipal University, Manipal, Karnaka, India.

DOI:

https://doi.org/10.22159/ajpcr.2018.v11i11.27553

Keywords:

Aortic dissection, Ectasia, Extended brilliance workstation, Multidetector computed tomography

Abstract

Objective: The normal size of the abdominal aorta is expected to be <3 cm though the size changes with age as well as workload. There is a need to know the variation in size of the abdominal aorta to avoid the formation of aneurysm and further complications.

Materials and Methods: This study was carried out at Kasturba Medical College after taking 130 patients considering the inclusion and exclusion criteria. 130 patients who all came for abdomen computed tomography (CT) were divided into 65 patients in each age group under 20–40 years and 40–80 years. The measurements of abdominal aorta were anteroposterior (AP) and right left (RL) measured at T12-L1 level on plain axial abdomen CT images on Extended Brilliance Workstation.

Result: We observed that there was a statistical significant difference in the average AP diameter between the two age groups (p<0.001). Another finding was a statistical significant difference in the average RL diameter between the two age groups (p<0.001), and, hence the size of abdominal aorta varies with age.

Conclusion: The proposed study concluded that there was variation in the size of abdominal aorta with age. These findings would be helpful in early detecting of aneurysm and in avoiding aortic dissection.

Downloads

Download data is not yet available.

Author Biography

Dolly Sharma, Department of Medical Imaging Technology, Charotar Institute of Paramedical Sciences, Charusat University, Changa, Gujarat, India.

Assistant professor,

Charotar Institute  of Paramedical Sciences, CHARUSAT UNIVERSITY, ANAND 388421

References

Erbel R, Eggebrecht H. Aortic dimensions and the risk of dissection. Heart 2006;92:137-42.

Devereux RB, de Simone G, Arnett DK, Best LG, Boerwinkle E, Howard BV, et al. Normal limits in relation to age, body size and gender of two-dimensional echocardiographic aortic root dimensions in persons ≥15 years of age. Am J Cardiol 2012;110:1189-94.

Hager A, Kaemmerer H, Rapp-Bernhardt U, Blücher S, Rapp K, Bernhardt TM, et al. Diameters of the thoracic aorta throughout life as measured with helical computed tomography. J Thorac Cardiovasc Surg 2002;123:1060-6.

Joh JH, Ahn HJ, Park HC. Reference diameters of the abdominal aorta and iliac arteries in the korean population. Yonsei Med J 2013;54:48-54.

Niryana W, Pagehgiri AW, Widyadharma PK. Mircosurgical clippning in the ruptured an aneurysm of anterior communicating artery: A case report. Asian J Pharm Clin Res 2017;10:7-9.

Johansson G, Markström U, Swedenborg J. Ruptured thoracic aortic aneurysms: A study of incidence and mortality rates. J Vasc Surg 1995;21:985-8.

Agmon Y, Khandheria BK, Meissner I, Schwartz GL, Sicks JD, Fought AJ, et al. Is aortic dilatation an atherosclerosis-related process? Clinical, laboratory, and transesophageal echocardiographic correlates of thoracic aortic dimensions in the population with implications for thoracic aortic aneurysm formation. J Am Coll Cardiol 2003;42:1076-83.

Bengtsson H, Bergqvist D, Jendteg S, Lindgren B, Persson U. Ultrasonographic screening for abdominal aortic aneurysm: Analysis of surgical decisions for cost-effectiveness. World J Surg 1989;13:266-71.

Wanhainen A, Bergqvist D, Björck M. Measuring the abdominal aorta with ultrasonography and computed tomography-difference and variability. Eur J Vasc Endovasc Surg 2002;24:428-34.

England A, Niker A, Redmond C. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms. Radiography 2010;16:173-81.

Diehm N, Kickuth R, Gahl B, Do DD, Schmidli J, Rattunde H, et al. Intraobserver and interobserver variability of 64-row computed tomography abdominal aortic aneurysm neck measurements. J Vasc Surg 2007;45:263-8.

Diehm N, Baumgartner I, Silvestro A, Herrmann P, Triller J, Schmidli J, et al. Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: Assessment of inter- and intraobserver variation. Vasa 2005;34:255-61.

Sariosmanoglu N, Ugurlu B, Karacelik M, Tuzun E, Yorulmaz I, Manisali M, et al. A multicentre study of abdominal aorta diameters in a turkish population. J Int Med Res 2002;30:1-8.

Länne T, Sonesson B, Bergqvist D, Bengtsson H, Gustafsson D. Diameter and compliance in the male human abdominal aorta: Influence of age and aortic aneurysm. Eur J Vasc Surg 1992;6:178-84.

Thompson SG, Ashton HA, Gao L, Scott RA. Multicentre aneurysm screening study group. Screening men for abdominal aortic aneurysm: 10 year mortality and cost effectiveness results from the randomized multicentre aneurysm screening study. Br Med J 2009;338:230-7.

Cosford PA, Leng GC. Screening for abdominal aortic aneurysm. Cochrane Database Syst Rev 2007;2:CD002945.

Lederle FA, Wilson SE, Johnson GR, Reinke DB, Littooy FN, Acher CW, et al. Variability in measurement of abdominal aortic aneurysms. Abdominal aortic aneurysm detection and management veterans administration cooperative study group. J Vasc Surg 1995;21:945-52.

Published

07-11-2018

How to Cite

Sharma, D., and V. T. “VARIATION IN THE SIZE OF ABDOMINAL AORTA MEASURED ON COMPUTED TOMOGRAPHY”. Asian Journal of Pharmaceutical and Clinical Research, vol. 11, no. 11, Nov. 2018, pp. 146-8, doi:10.22159/ajpcr.2018.v11i11.27553.

Issue

Section

Original Article(s)