DEVELOPMENT AND VALIDATION OF HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY METHOD FOR SIMULTANEOUS ESTIMATION OF NEBIVOLOL HYDROCHLORIDE AND CILNIDIPINE

Authors

  • MINAL R. GHANTE Sinhgad Technical Education Society, Smt. Kashibai Navale College of Pharmacy, Pune.
  • NATASHA AKHADE Sinhgad Technical Education Society, Smt. Kashibai Navale College of Pharmacy, Pune.
  • PREETI GOTA Gahlot Institute of Pharmacy, Koparkhaine, Navi Mumbai.
  • ATUL NIKAM Sinhgad Technical Education Society, Smt. Kashibai Navale College of Pharmacy, Pune.
  • SUPRIYA JAGTAP Sinhgad Technical Education Society, Smt. Kashibai Navale College of Pharmacy, Pune.
  • VANDANA NIKAM Sinhgad Technical Education Society, Smt. Kashibai Navale College of Pharmacy, Pune.

DOI:

https://doi.org/10.22159/ajpcr.2019.v12i4.30569

Keywords:

Method development high-performance thin-layer chromatography, Nebivolol hydrochloride, Cilnidipine, International Council for Harmonisation

Abstract

Objective: The proposed method describes method development and validation of nebivolol hydrochloride and cilnidipine in combined pharmaceutical tablet dosage form by high-performance thin-layer chromatography (HPTLC) having adequate specificity, sensitivity, and reproducibility.

Methods: Nebivolol hydrochloride and cilnidipine drug combination is used for the treatment of hypertension. Precoated aluminum plates with silica gel 60 F254 (E-Merck, Germany) were used for the chromatographic separation which was carried using chloroform:glacial acetic acid:methanol, in 8.5:1:0.5 (v/v/v) as a mobile phase. HPTLC separation of two drugs was carried by densitometric measurement at 270 nm.

Reults: The drugs were satisfactorily resolved with retardation factor values of 0.0.29±0.008 and 0.69±0.007 for nebivolol hydrochloride and cilnidipine, respectively. The method was found to be linear in the range of 100–1000 ng/spot and 50–500 ng/spot for nebivolol hydrochloride and cilnidipine, respectively. The correlation coefficient was found to be 0.989 and 0.996 for nebivolol hydrochloride and cilnidipine, respectively. Limit of detection and limit of quantitation values were 16.395 ng/band and 49.681 ng/band and 31.788ng/band and 96.328 ng/band, respectively. The mean recovery was found to be 100.570–101.936 and 100.269–101.333 for nebivolol hydrochloride and cilnidipine, respectively. The intra- and inter-day precision was found to be within the limit.

Conclusion: A simple, accurate, precise, and sensitive HPTLC method has been developed and validated in combined pharmaceutical tablet dosage form for simultaneous estimation of nebivolol hydrochloride and cilnidipine.

Downloads

Download data is not yet available.

References

Fuchs FD. Essential of Hypertension. New york: Springer; 2017.

Available from: https://www.1mg.com/generics/nebivolol- cilnidipine -402479. [Last accessed on 2018 Nov 20].

Indian Pharmacopoeial Commission. Indian Pharmacopoeia. Ghaziabad: Ministry of Health and Family Welfare Government of India; 2014. p. 2310-2.

Godfraind T. Discovery and development of calcium channel blockers. Front Pharmacol 2017;8:286.

Patel BD. Development and validation of reversed phase high performance liquid chromatography method for simultaneous estimation of nebivolol HCl and cilnidipine in combined tablet dosage form. Pharm Biol Eval 2016;3 Suppl 2:208-14.

Patel PR, Patel N, Shah SK. Analytical method development and validation for simultaneous estimation of nebivolol hydrochloride and cilnidipine in combined dosage form. J Chem Pharm Res 2015;7:951 60.

Aruna G, Bharathi K, Prasad KV. Development and validation of bioanalytical HPLC method for simultaneous estimation of cilnidipine and nebivolol in human plasma. Int J Pharm Pharm Sci 2017;9 Suppl 10:253-9.

Thula KC, Patel DM, Maheshwari DG. Development and validation of first order derivative UV spectrophotometric method for simultaneous estimation of nebivolol and cilnidipine in pharmaceutical formulation. Int J Pharm Sci Rev Res 2015;31 Suppl 1:243-7.

Patel PR, Patel N, Shah SK. Analytical method development and validation for simultaneous estimation of nebivolol hydrochloride and cilnidipine in combined dosage form. J Chem Pharm Res 2015;7:951 60.

Patel ND, Mehta1 RS, Captain AD, Karkhanis VV, Patel PD, Chavda AA. Development and validation of stability indicating RP-HPLC method for simultaneous estimation of nebivolol hydrochloride and cilnidipine in tablet dosage form. J Pharm Sci Biosci Res 2017;7 Suppl 1:140-7.

Kumbhar ST, Chougule GK, Tegeli VS, Gajeli GB, Thorat YS, Shivsharan US. A validated HPTLC method for simultaneous quantification of nebivolol and hydrochlorothiazide in bulk and tablet formulation. Int J Pharm Sci Drug Res 2011;3 Suppl 1:62-6.

Kokilambigai KS, Lakshmi KS, Kumar A, Chandrayan G, Satyam K, Singh MK. Spectrophotometric estimation of cilnidipine in bulk and pharmaceutical dosage form using N-(1-Naphthyl) ethylene diamine dihydrochloride. Int J Pharm Pharm Sci 2014;6 Suppl 9:576-8.

Shah DM, Doshi DB. Development and validation of HPTLC method for simultaneous estimation of nebivolol hydrochloride and cilnidipine in combined pharmaceutical tablet dosage form. Int J Pharma Res Rev 2016;5 Suppl 6:1-7.

ICH Harmonized Tripartite Guideline Validation of Analytical Procedures: Text and Methodology, Q2 (R1); 2005. p. 1-28.

Published

07-04-2019

How to Cite

MINAL R. GHANTE, NATASHA AKHADE, PREETI GOTA, ATUL NIKAM, SUPRIYA JAGTAP, and VANDANA NIKAM. “DEVELOPMENT AND VALIDATION OF HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY METHOD FOR SIMULTANEOUS ESTIMATION OF NEBIVOLOL HYDROCHLORIDE AND CILNIDIPINE”. Asian Journal of Pharmaceutical and Clinical Research, vol. 12, no. 4, Apr. 2019, pp. 347-50, doi:10.22159/ajpcr.2019.v12i4.30569.

Issue

Section

Original Article(s)