VALIDATION OF WARFARIN ANALYSIS METHOD IN HUMAN BLOOD PLASMA USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH FLUORESCENCE DETECTION

Authors

  • NORISCA ALIZA PUTRIANA Department of Pharmaceutical and Formulation Technology, Faculty of Pharmacy, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, Indonesia
  • TAOFIK RUSDIANA Department of Pharmaceutical and Formulation Technology, Faculty of Pharmacy, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, Indonesia
  • TINA ROSTINAWATI Department of Biology Pharmacy, Faculty of Pharmacy, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, Indonesia
  • MOHAMMAD RIZKI AKBAR Department of Cardiovascular, Faculty of Medicine, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, Indonesia
  • ILMA NURFUADAH Department of Pharmaceutical and Formulation Technology, Faculty of Pharmacy, Universitas Padjadjaran, Jalan Raya Bandung-Sumedang KM 21, Jatinangor 45363, Indonesia

DOI:

https://doi.org/10.22159/ijap.2022.v14s5.27

Keywords:

Warfarin, Validation, HPLC Fluorescence, European medicine agency

Abstract

Objective: Validation of analysis method is important, especially in analyzing narrow-index drugs such as warfarin (WF). This study aimed to obtain a validated method of analyzing warfarin in human plasma according to European Medicine Agency guidelines.

Methods: The optimum conditions for the analysis of warfarin in human plasma using fluorescence detector HPLC with Chiralcel OD-RH column (4.6 x 150 mm i.d., 5μm); Chiralcel OD-RH guard column (4.0 x 10 mm, 5μm), column temperature 45 °C. The mobile phase used was acetonitrile: phosphate buffer pH 2 (40:60), with an isocratic flow rate of 1 ml/min and an injection volume of 20 μl. Excitation and emission wavelengths were 310 and 350 nm (warfarin) and 300 and 400 nm (griseofulvin). The retention time of griseofulvin was 6-7.5 min; R-warfarin was 10-11.5 min; S-warfarin was 14-16 min.

Results: The result of this validation obtained the optimum condition. This method yielded LOD values of 0.0674 ppm (R-warfarin) and 0.0897 ppm (S-warfarin). LOQ values were 0.225 ppm (R-warfarin) and 0.298 ppm (S-warfarin). Linearity at concentrations of 0.2-3 ppm with the line equation y = 0.0705x+0.0704 with R2 = 0.978 for R-warfarin and y = 0.0513x+0.0297 with R² = 0.9924 for S-warfarin. 75% of the seven concentrations met the reverse concentration requirements, which were below±15%. This method met the requirements of accuracy and precision within and between runs, selectivity and carryover where the %RSD and %diff values were below±15%

Conclusion: This analytical method can be declared valid and can be used for sample measurement in warfarin pharmacokinetic studies.

Downloads

Download data is not yet available.

References

PIONAS. Natrium warfarin; 2021. Available from: https://pionas.pom.go.id/monografi/natrium-warfarin

Alshogran OY, Ocque AJ, Leblond FA, Pichette V, Nolin TD. Validation and application of a simple UHPLC-MS-MS method for the enantiospecific determination of warfarin in human urine. J Chromatogr Sci. 2016;54(4):554-60. doi: 10.1093/chromsci/bmv186, PMID 26657732.

NCBI. Warfarin; 2021. Available from: https://pubchem.ncbi.nlm.nih.gov/compound/warfarin. [Last accessed on 06 Dec 2022]

FDA. Crystalline (warfarin sodium for injection, USP). Warfarin Sodium Tablets Usp. 2011:1-39.

Kim SY, Kang JY, Hartman JH, Park SH, Jones DR, Yun CH. Metabolism of R- and S-warfarin by CYP2C19 into four hydroxywarfarins. Drug Metab Lett. 2012;6(3):157-64. doi: 10.2174/1872312811206030002, PMID 23331088.

Sholihah S, Putriana NA, Pratiwi R. Review metode analisis warfarin dalam plasma dengan berbagai instrumen. J Sains Farm Klin. 2021;8(2):128.

Qayyum A, Najmi MH, Khan AM, Abbas M, Naveed AK, Jameel A. Determination of S- and R-warfarin enantiomers by using modified HPLC method. Pak J Pharm Sci. 2015;28(4):1315-21. PMID 26142522.

Chua YA, Abdullah WZ, Yusof Z, Gan SH. Validation of HPLC and liquid-liquid extraction methods for warfarin detection in human plasma and its application to a pharmacokinetics study. ASMScJ. 2019;12(June):1-10. doi: 10.32802/asmscj.2019.215.

Nazareth C, Pereira S. A review on chiral stationary phases for separation of chiral drugs. Int J Pharm Phytopharmacol Res. 2020;10(3):77-91.

Chapter K. Chiral chromatography and its application to the pharmaceutical industry: a review. Chemsearch Journal. 1996;2(1):8-11.

Susanti M, Dachriyanus. Kromatografi cair kinerja tinggi. Padang: Andalas University Press; 2014.

EMA. International Council of Harmonisation Guideline M10 on Bioanalytical Method Validation; 2019. p. 44.

Putriana NA, Rusdiana T, Rostinawati T, Akbar MR, Saputri FA, Utami S. Validation of warfarin enantiomer analysis method in plasma using a high-performance liquid chromatography fluorescence detector. J Adv Pharm Technol Res. 2022;13(1):18-24. doi: 10.4103/japtr.japtr_259_21, PMID 35223436.

Heidorn M. The role of temperature and column thermostatting in liquid chromatography. Thermo Fish Sci. 2016.

NCBI. Griseofulvin; 2021. Available from: https://pubchem.ncbi.nlm.nih.gov/compound/amudane. [Last accessed on 06 Dec 2022]

Lomonaco T, Ghimenti S, Piga I, Onor M, Melai B, Fuoco R. Determination of total and unbound warfarin and warfarin alcohols in human plasma by high-performance liquid chromatography with fluorescence detection. J Chromatogr A. 2013;1314:54-62. doi: 10.1016/j.chroma.2013.08.091, PMID 24054125.

Published

27-12-2022

How to Cite

PUTRIANA, N. A., RUSDIANA, T., ROSTINAWATI, T., AKBAR, M. R., & NURFUADAH, I. (2022). VALIDATION OF WARFARIN ANALYSIS METHOD IN HUMAN BLOOD PLASMA USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH FLUORESCENCE DETECTION. International Journal of Applied Pharmaceutics, 14(5), 132–138. https://doi.org/10.22159/ijap.2022.v14s5.27

Issue

Section

Original Article(s)

Most read articles by the same author(s)

<< < 1 2