IDENTIFICATION, SEPARATION, AND CHARACTERIZATION OF DEGRADATION PRODUCTS OF TRIAMCINOLONE HEXACETONIDE USING LC AND LC-MS/MS

Authors

  • BHAVNA SUNIL MAHAJAN Sinhgad Institute of Pharmacy, Narhe, Pune-411041, Affiliated to Savitribai Phule Pune University, Ganeshkhind, Pune -411007, India. Vishwakarma University School of Pharmacy, Pune-411048, India https://orcid.org/0009-0000-1770-1100
  • PANKAJ B. MINIYAR Sinhgad Institute of Pharmaceutical Sciences, Kusgaon (Bk), Lonavala-410401 Pune, Affiliated to Savitribai Phule Pune University, Ganeshkhind, Pune-411007, India

DOI:

https://doi.org/10.22159/ijap.2024v16i3.50122

Keywords:

Stress degradation product, LC-MS/MS, Triamcinolone , hexacetonide, Validation

Abstract

Objective: The study aimed to separate the forced degradation products of Triamcinolone hexacetonide using HPLC and characterize the degradation product by LC-MS/MS fragmentation pattern.

Methods: Triamcinolone hexacetonide (THA) and its primary degradation products were identified using a liquid chromatography-mass spectrometry/Mass spectrometry (LC-MS/MS) approach. The degradation study was based on in-depth stress testing with acid, base, peroxide, heat, and light. A Zorbax SB C18 column and a greener mobile phase composed of methanol and 10 mmol ammonium acetate buffer in water at pH 3 were employed to accomplish separation and quantitation at a flow rate of 0.7 ml/min in an isocratic mode with a 239 nm detection wavelength.

Results: A major degradation product of the drug was obtained in acidic and alkaline stress conditions. The drug was found to be stable for all other stress conditions. The LC-MS/MS analysis results of the active pharmaceutical ingredient and resulting product after degradation were interpreted to identify the novel degradation product and fragments. The developed method was validated as per International Council for Harmonization (ICH) guidelines. The square root of the correlation coefficients, which indicated linearity for THA in 50 to 150 % of the workload, was 0.99. Method Precision assay was performed on six different preparations, percentage relative standard deviation (% RSD) of assay value is 0.17 % and system precision is 0.30 %. In accuracy, overall % RSD of 50 %, 100 %, and 150 % in triplicate is 0.95.

Conclusion: It is concluded that the drug is stable to all other stress conditions except for acidic and alkaline stress conditions and generates a novel degradation product. The developed LC (Liquid chromatography) method separates and identifies the degradation product.

Downloads

Download data is not yet available.

References

Scherer J, Rainsford KD, Kean CA, Kean WF. Pharmacology of intra-articular triamcinolone. Inflammopharmacology. 2014;22(4):201-17. doi: 10.1007/s10787-014-0205-0, PMID 24824076.

Duclos M. Use and abuse of anabolic steroids and glucocorticoids in sport. Ann Endocrinol (Paris). 2007;68(4):308-14. doi: 10.1016/j.ando.2007.06.022, PMID 17689473.

Thuyne WV, Delbeke FT. Declared use of medication in sports. Clin J Sport Med. 2008;18(2):143-7. doi: 10.1097/JSM.0b013e318163f220, PMID 18332689.

Guinot M, Duclos M, Idres N, Souberbielle JC, Megret A, Le Bouc Y. Value of basal serum cortisol to detect corticosteroid-induced adrenal insufficiency in elite cyclists. Eur J Appl Physiol. 2007;99(3):205-16. doi: 10.1007/s00421-006-0332-4, PMID 17089154.

Dvorak J, Feddermann N, Grimm K. Glucocorticosteroids in football: use and misuse. Br J Sports Med. 2006;40Suppl 1:i48-54. doi: 10.1136/bjsm.2006.027599, PMID 16799104.

Fitch K. Glucocorticoids at the olympic games: state-of-the-art review. Br J Sports Med. 2016;50(20):1267. doi: 10.1136/bjsports-2016-096664, PMID 27474388.

Duclos M. Evidence on ergogenic action of glucocorticoids as a doping agent risk. Phys Sportsmed. 2010;38(3):121-7. doi: 10.3810/psm.2010.10.1817, PMID 20959705.

Keller Wood ME, Dallman MF. Corticosteroid inhibition of ACTH secretion. Endocr Rev. 1984;5(1):1-24. doi: 10.1210/edrv-5-1-1, PMID 6323158.

Henzen C, Suter A, Lerch E, Urbinelli R, Schorno XH, Briner VA. Suppression and recovery of adrenal response after short-term, high-dose glucocorticoid treatment. Lancet. 2000;355(9203):542-5. doi: 10.1016/S0140-6736(99)06290-X, PMID 10683005.

Haritha Kumari M, Khandapu BMK, Raju RR. Liquid chromatography dependent stability indicating methodology: development and authentication for formulations of capsule type containing tegafur, gimeracil, and oteracil. Int J App Pharm. 2023;15:71-81. doi: 10.22159/ijap.2023v15i4.47831.

Pozo OJ, Ventura R, Monfort N, Segura J, Delbeke FT. Evaluation of different scan methods for the urinary detection of corticosteroid metabolites by liquid chromatography-tandem mass spectrometry. J Mass Spectrom. 2009;44(6):929-44. doi: 10.1002/jms.1568, PMID 19235930.

Matabosch X, Pozo OJ, Papaseit E, Farre M, Marcos J, Segura J. Detection and characterization of triamcinolone acetonide metabolites in human urine by liquid chromatography/tandem mass spectrometry after intramuscular administration. Rapid Commun Mass Spectrom. 2014;28(16):1829-39. doi: 10.1002/rcm.6965, PMID 25559453.

Matabosch X, Pozo OJ, Perez Mana C, Papaseit E, Marcos J, Segura J. Evaluation of the reporting level to detect triamcinolone acetonide misuse in sports. J Steroid Biochem Mol Biol. 2015;145:94-102. doi: 10.1016/j.jsbmb.2014.09.018, PMID 25260353.

Chang CW, Huang TY, Tseng YC, Chang Chien GP, Lin SF, Hsu MC. Positive doping results caused by the single-dose local injection of triamcinolone acetonide. Forensic Sci Int. 2014;244:1-6. doi: 10.1016/j.forsciint.2014.07.024, PMID 25126738.

Ventura R, Matabosch X, Segura J. Bioanalytical techniques in discrimination between therapeutic and abusive use of drugs in sport. Bioanalysis. 2016;8(9):965-80. doi: 10.4155/bio.15.253, PMID 26884281.

Derendorf H, Mollmann H, Gruner A, Haack D, Gyselby G. Pharmacokinetics and pharmacodynamics of glucocorticoid suspensions after intra-articular administration. Clin Pharmacol Ther. 1986;39(3):313-7. doi: 10.1038/clpt.1986.45, PMID 3948470.

Byrne FP, Saimeng J, Giulia P, Tabitha MP, James HC, Andrew TJ. Tools and techniques for solvent selection: green solvent selection guides. Sustain Chem Process. 2016;4:1-24.

ICH. Geneva. (R2) Guideline: Stability testing of new drug substances and products, international Conference on Harmonization; 2005. p. Q1A.

ICH. Q2 (R1) validation of analytical procedure: test and methodology, International Conference on Harmonization, Geneva; 2005.

Bodke SS, Bhangale CJ, Bhandare SN. Stability indicating UPLC method for estimation of benazepril and hydrochlorothiazide in bulk and combined dosage form. Int J Pharm Pharm Sci. 2024;16:22-9. doi: 10.22159/ijpps.2024v16i1.49457.

Reddy BM, Ashok Reddy BR, Naidu UT, Kumar AA, Vooturi R. A simple RP-HPLC method development and verification of the dissolution of bromelain-a complex mixture of proteolytic enzymes, in delayed-release tablets. Int J Pharm Pharm Sci. 2024;16:37-44. doi: 10.22159/ijpps.2024v16i1.49569.

van Heugten AJP, de Boer W, de Vries WS, Markesteijn CMA, Vromans H. Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation. J Pharm Biomed Anal. 2018;149:265-70. doi: 10.1016/j.jpba.2017.11.026, PMID 29127908.

Abbas SS, Hegazy MA, Hendawy HAM, Weshahy SA, Abdelwahab MH. Resolution and quantitation of triamcinolone acetonide and its co-formulated drug in the presence of its impurities and degradation products by HPTLC and HPLC. J AOAC Int. 2018;101(4):981-91. doi: 10.5740/jaoacint.16-0422, PMID 28903833.

Published

07-05-2024

How to Cite

SUNIL MAHAJAN, B., & MINIYAR, P. B. (2024). IDENTIFICATION, SEPARATION, AND CHARACTERIZATION OF DEGRADATION PRODUCTS OF TRIAMCINOLONE HEXACETONIDE USING LC AND LC-MS/MS. International Journal of Applied Pharmaceutics, 16(3), 326–331. https://doi.org/10.22159/ijap.2024v16i3.50122

Issue

Section

Original Article(s)